Mixing
Liquid components A and B are poured into the mixing bucket and mixed for 30 seconds. Ensure that the containers are completely emptied before mixing. Once the liquid resin mixture is uniform, add half of component C and mix for approximately 1 minute until the mixture is homogeneous. Make sure the first half of component C is fully blended with the resin. Then repeat the process by adding the remaining half of component C. Mixing time may vary slightly depending on ambient and material temperatures. Once the mixture is smooth and free of lumps, bring the material to the application area without delay.
Application instructions
Apply the coating with a rubber squeegee and finish by rolling.
Notes
The components must be mixed mechanically. The ideal ambient and installation temperature range is between +12°C and +25°C. It is important to consider the effect of the dew point to avoid moisture formation in the primer.
Storage and handling of waste
See the separate storage and disposal instructions https://www.fescon.fi/en/material-bank